Information about the operating instructions
About these operating instructions
- Warning! Read and understand all accompanying documentation, including but not limited to instructions, safety warnings, illustrations, and specifications provided with this product. Familiarize yourself with all the instructions, safety warnings, illustrations, specifications, components, and functions of the product before use. Failure to do so may result in electric shock, fire, and/or serious injury. Save all warnings and instructions for future reference.
- products are designed for professional users and only trained, authorized personnel are permitted to operate, service and maintain the products. This personnel must be specifically informed about the possible hazards. The product and its ancillary equipment can present hazards if used incorrectly by untrained personnel or if used not in accordance with the intended use.
- The accompanying documentation corresponds to the current state of the art at the time of printing. Please always check for the latest version on the product’s page on Hilti’s website. To do this, follow the link or scan the QR code in this documentation, marked with the symbol .
- Ensure that these operating instructions are with the product when it is given to other persons.
Explanation of symbols used
Warnings
Warnings alert persons to hazards that occur when handling or using the product. The following signal words are used:Symbols in the documentation
The following symbols are used in this document:Read the operating instructions before use. |
|
Instructions for use and other useful information |
|
Dealing with recyclable materials |
|
Do not dispose of electric equipment and batteries as household waste |
Symbols in the illustrations
The following symbols are used in illustrations:These numbers refer to the corresponding illustrations found at the beginning of these operating instructions |
|
The numbering reflects the sequence of operations shown in the illustrations and may deviate from the steps described in the text |
|
Item reference numbers are used in the overview illustrations and refer to the numbers used in the product overview section |
|
This symbol is intended to draw special attention to certain points when handling the product. |
Sticker on the product / on the packaging
Comply with the warnings about handling button-cell batteries.Safety
General safety instructions
Read all safety instructions and other instructions.Keep all safety instructions and other instructions for future reference.
General safety instructions
- Do not forcibly open the product.
- Please observe the following with regard to installation of the product on electric devices:
- Do not cover a type identification plate or other labels.
- Do not cover any openings in the casing of the item of equipment.
- Do not obstruct switches, displays and warning lights.
- To avoid surface damage or chemical reactions, check that the adhesive is compatible with the surface before applying the ON!Track smart tag.
- Keep away from children.
Careful handling and use of button-cell batteries
- Never swallow button-cell batteries. Severe internal caustic burns or death can result within 2 hours of swallowing a button-cell battery.
- Make sure that button-cell batteries are inaccessible to children. Call a poison control center to obtain information on treatment if there is any suspicion that a button-cell battery has been swallowed or inserted into a body orifice.
- Use only the button-cell batteries stated in these operating instructions. Do not use any other button-cell batteries or other power supply.
- Do not attempt to recharge non-rechargeable button-cell batteries. The button-cell battery can develop a leak, explode, catch fire and injure persons.
- Do not force-discharge, charge, disassemble or incinerate the button-cell battery. Do not heat the button-cell battery to a temperature above the maximum temperature stated by the manufacturer. Otherwise there is a risk of injury by degassing, leakage or explosion leading to chemical burns.
- Remove discharged button-cell batteries and recycle or dispose of them immediately in accordance with your local regulations. Keep button-cell batteries out of reach of children. Do NOT dispose of button-cell batteries in household waste and do not incinerate them. Discharged button-cell batteries can develop leaks and so damage the product or injure persons.
- Even discharged button-cell batteries can lead to serious injuries or death. Do not treat discharged button-cell batteries with less care than new batteries.
- Do not bring a damaged button-cell battery into contact with water. In the presence of water, escaping lithium can produce hydrogen and so lead to a fire or an explosion, or cause injury to persons.
Description
Intended use
The Hilti ON!Track smart tag AI T320 makes it possible to clearly identify a construction asset by way of wireless data transmission or a Data Matrix code. After activation, the AI T320 continuously transmits a radio signal that allows the user of the Hilti ON!Track system to determine the location of the construction asset. A smartphone app and a Web application for the management of construction assets is available from Hilti . The battery of the AI T320 is not replaceable.Items supplied
20 x AI T320, operating instructionsOther system products approved for use with this product can be found at your local Hilti Store or at: www.hilti.group
Technical data
Dimensions (length x width x height) |
32.3 mm x 22.3 mm x 5.3 mm (1.27 in x 0.88 in x 0.21 in) |
Degree of protection |
IP 67 and IP 69 |
Operating temperature |
−20 ℃ … 60 ℃ (−4 ℉ … 140 ℉) |
Storage temperature |
−20 ℃ … 30 ℃ (−4 ℉ … 86 ℉) |
Battery (not replaceable) |
CR2032 button cell |
Battery life (at room temperature) |
4 years |
Signal range (can vary greatly depending on surrounding conditions) |
30 m (98 ft - 5 in) |
Signal interval |
7 s |
Frequency |
2,402 MHz … 2,480 MHz |
Maximum emitted transmission power |
4.0 dBm |
Activating
- Remove the AI T320 from the packaging and lay it down flat.
- Turn the AI T320 through 180 ° and lay it down again.
- This briefly activates the AI T320 and it transmits a signal for 30 seconds.
- This briefly activates the AI T320 and it transmits a signal for 30 seconds.
- Within 30 seconds, add the AI T320 in the Hilti ON!Track app.
- The AI T320 is now permanently activated.
- The AI T320 is now permanently activated.
Transport
Disposal
The Hilti ON!Track smart tag AI T320 contains a permanently installed button-cell battery. For disposal, therefore, treat the product as a button-cell battery.Do not dispose of the AI T320 as household waste. Instead, dispose of it in accordance with national regulations.
Manufacturer’s warranty
- Please contact your local Hilti representative if you have questions about the warranty conditions.
FCC statement (applicable in US)/IC statement (applicable in Canada)
However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by taking the following measures:- Re-orient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment to a power outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced TV/radio technician for assistance.
Operation is subject to the following two conditions:
- This device shall cause no harmful interference.
- This device must accept any interference received, including interference that may cause undesired operation.
Further information
RoHS (Restriction of Hazardous Substances) This table is valid for the China market.Country-specific approvals
The sections below contain approval requirements of the corresponding markets.
Conditions : Singapore
DA105282
Conditions : Mexico
Product information
Model |
2282471 2273202 |
País de origem: Tailândia
Para maiores informações, consulte o site da ANATEL – www.anatel.gov.br
Declaration of conformity
Declaration of conformityThe manufacturer declares, on his sole responsibility, that the product described here complies with the applicable legislation and standards.The technical documentation is filed here:
Hilti Entwicklungsgesellschaft mbH | Tool Certification | Hiltistrasse 6 | D-86916 Kaufering, Germany
Product information
Model |
2282471 2273202 |
UK Declaration of Conformity
Declaration of conformityThe manufacturer declares, on his sole responsibility, that the product described here complies with the applicable legislation and standards.The technical documentation is filed here:
Hilti Entwicklungsgesellschaft mbH | Tool Certification | Hiltistrasse 6 | D-86916 Kaufering, Germany
Product information
Model |
2282471 2273202 |